Safety Interlock and Process Control Shutters

Shutters in this group are designed for high optical
power and damage thresholds, but with lower
emphasis on speed.

The Safety Interlock Shutter is normally kept
open for long periods of time, closing only for breaches
in the safety system or at the end of an experiment.

The Process Control Shutter is used at frequent intervals, allowing equipment to move or change in between optical exposures. An example would be laser cutting. At various points, the shutter would block the laser to allow table repositioning and cutting to resume.

All Safety Interlock and Process Control Shutters are failsafe and close upon power loss. They are not dependent on gravity to close.

Switching speed requirements for safety and process applications are moderate. The flexure technology used in these products offer inherent fast switching without developing large heat loads in the electromagnet. 

Many of these applications can use low power, simple electronic drive systems. See our Application Notes page for more on OEM and user built drive circuits. Our Shutter Controllers product line offers the most convenient way to drive the shutter and extract all benefits of the shutter design.

Position sensors are on most of the models, providing a safety or process circuit with verification that the shutter did indeed open or close as it was instructed to do from the power circuit.

These position sensors are completely independent of the power circuit. They audit the physical movement of the flexure blade, with either solid-state opto-interrupters for smaller apertures, or mechanical micro-switches for larger apertures.

The solid-state sensors are powered from regulated 5 VDC at about 20 mA current budget. There are two output leads which yield a logic hi or lo depending on shutter state.

Our CX2450B controller series provide the 5 V and offer the output conveniently on a terminal strip at the rear of the controller.

The output signals are logic ready TTL totem pole outputs, able to drive up to about 5 mA. This signal can be used to control software or to drive power electronics for warning light illumination.

The mechanical micro-switches provide contact closure for the open and closed states. There are two leads for each switch. Typically switches are operated at 5, 12, 24 VDC at a few tens of mA, but are rated for use at several Amps. Contact resistance is less than 5 ohms with cable loss included.

Many of these models are driven with user-built circuitry. Switching speed is very dependent on the circuit, with more advanced circuits providing faster speeds. In general, all models close in less than 50 msec, with an approximate rule of 4 msec per mm of aperture diameter.

Speeds shown below represent switching using our recommended CX2450B controller.

MODEL

FEATURES  

APPLICATIONS

LSH4

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  Fits Standard 1.75"
    HENE Laser Tubes

*  4 mm Aperture

*  Simple 12 V Drive

*  Low Cost

*  10 Hz Cycling

*  No Position Sensors

*  Safety Interlock

*  Strobe

*  Entertainment Lighting

*  Exposures

LST18

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  Small Package

*  Simple 12 V Drive

*  Up to 500m W Optical

*  Thru-hole and Side Mounting

*  2.5 mm Aperture

*  Up to 5 Hz Cycling

*  No Position Sensors

*  OEM Safety

*  Instruments

LST200SLP

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  Fast Switching for Processing

*  2.3 mm Aperture

*  Smallest Package

*  No Position Sensors

*  OEM Requiring Speed
    and Low Cost

*  Fits in Tight Zones

*  Highest Reliability

*  Biotech Exposures

 

 

LST4WBK2

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  4 mm Aperture

*  Smallest Package
    with Logic Sensors

*  Cycling up to 5 Hz

*  Standard Gold Optic,
    Custom Optics Available

*  Typical 10 ms Switching

*  Up to 25 W Optical

*  OEM Safety Interlock

*  High Rep Rate DPSS

*  Thin Working Zones

 

LST50

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  Efficient 24 V Drive

*  6.3 mm Aperture

*  Lowest Outgassing

*  10 W Optical

*  10 msec Switching

*  Teflon Cable

*  Larger Beam Formats

*  UV Sources

*  Exposure Processing

 

 

LST400

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  8 mm Aperture

*  Up to 25 W

*  Broadband Optic

*  Cycling to 3 Hz

*  20 ms Switching

*  Logic Sensors

*  Safety Interlock

*  Slow Processing

*  Diverging Beams

*  Tight Zones

*  OEM Integration

 

 

LS055W8

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  8 mm Aperture

*  Grazing Incidence

*  Up to 1 J/cm2

*  Up to 200W Optical

*  Processing to 10 Hz

*  Multiple Optic Options

*  Logic or Mechanical
    Position Sensors

*  High Power Interlock

*  Q-Switched Lasers

*  Fast Processing

*  OEM Integration

*  X-Ray Beams

 

 

LS055S3W8

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  12 mm Aperture

*  Up to 5 Hz Cycling

*  All Other Features and
    Options Same as LS055W8

*  Same as LS055W8

 

 

LSTXY-W8

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  14 mm Aperture

*  Dielectric Optics

*  Up to 5J/cm2

*  Mechanical Switches

*  Optics Options

*  2 Hz Cycling

*  Chiller Plate Option

*  1.0 Inch Thick

*  High Energy Pulses

*  Interlock

*  Thin Zones

*  Multi-line Lasers

 

 

 LSTXY-S1

Specification Data Sheet

Mechanical Drawing

Electrical Drive Data

*  20 mm Aperture

*  1.5 Inch Thick

*  1/4" Slot Mounting

*  Same As LSTXYW8
    with Larger Beams